Thermo King offers tech tips to increase equipment efficiency

RP news wires

A good maintenance program will save energy, time and money. Thermo King offers its customers “tech tips” to improve maintenance programs and maximize equipment efficiency and run time.

Thermo King Tech Tips:

Engines: Any time you replace an engine we recommend you install a new oil pressure switch, a new water temperature switch and a new coolant thermostat.

Compressor: When replacing a compressor always replace the drier and install a compressor oil filter kit.  Thermo King also recommends running the unit for a few hours at testing with the oil test kit to validate the compressor oil is acceptable.  Always remember to closely inspect the compressor drive bushings for wear.

Alternator: Any time you change an alternator, we recommend installing a new drive belt to ensure maximum uptime before the next related service.

Starter: Any time you replace a starter, always test the battery and the charging system for performance.

Refrigeration: Any time a refrigeration system is open for service we recommend you change the drier to assure maximum system performance.  If the system was open for any amount of time, we also recommend testing the compressor oil with an oil test kit to assure the oil is not contaminated.

About Ingersoll Rand
Ingersoll Rand is a global diversified industrial firm providing products, services and solutions to enhance the quality and comfort of air in homes and buildings, transport and protect food and perishables, secure homes and commercial properties, and enhance industrial productivity and efficiency. Driven by a 100-year-old tradition of technological innovation, Ingersoll Rand enables companies and their customers to create progress.  